Page 17
© 2015 Sensata Technologies
Installation
MS-PAE Inverter/Charger
(on MMPxxx-30D Enclosure
with hood and backplate)
ACLD-40
Diversion
Controller
Inverter AC Terminal Block
(Input and Output Wiring)
AC GROUNDS
(to Sub Panel)
INV OUT (HOT 2)
(from inverter H2 Out)
INV OUT (HOT 1)
(from inverter H1 Out)
ACLD Terminal Block
(Input and Output Wiring)
AC NEUTRAL
(from inverter Neutral)
SUB-PANEL (LEG 1)
(to Sub-Panel/AC Loads)
AC NEUTRAL
(to Sub-Panel Neutral)
SUB-PANEL (LEG 2)
(to Sub-Panel/AC Loads)
PRIMARY LOAD (L2)
(to Diversion Load)
PRIMARY LOAD (L1)
(to Diversion Load)
SECONDARY LOAD (L2)
(to Diversion Load)
SECONDARY LOAD (L1)
(to Diversion Load)
AC LEG 1 IN
(from Main Panel)
AC LEG 2 IN
(from Main Panel)
INV HOT 1 OUT
(to Sub-Panel via ACLD)
AC NEUTRAL
(to Sub-Panel via ACLD)
AC NEUTRAL
(from Main Panel)
INV HOT 2 OUT
(to Sub-Panel via ACLD)
3
9
8
7
6
5
4
2
1
3
6
5
4
2
1
E
G
INV HOT 2 OUT
(from ACLD to Sub-Panel)
6 5 4 3 2 1
MMPxxx-30D AC Terminal Block
(Input and Output Wiring)
D
A
B
C
A
B
C
D
E
F
F
G
INV HOT 1 OUT
(from ACLD to Sub-Panel)
INV NEUTRAL OUT
(from ACLD to Sub-Panel)
INV HOT 2 IN
(from Main Panel)
INV HOT 1 IN
(from Main Panel)
INV NEUTRAL IN
(from Main Panel)
Figure 2-7, AC Wiring from Inverter to ACLD